When connecting to the UPF port for the PFCP protocol (8805) and sending
an association setup request followed by a session establishment request
with a PDI Network Instance set to ‘internet’, it causes a stack corruption
to occur.
So, ogs_fqdn_parse() fixed.
Confirmation for non-cleartext IE should only be applied
to the initial NAS message. Registration requests and Service requests
with UplinkNASTransport do not have to.
1. If UE does not use a NAS container for Non-cleartext IEs,
Open5GS AMF will send Registration reject message.
2. If UE sends Non-cleartext IEs without Integrity-protected,
Open5GS AMF will send Registration reject message.
3. If UE does not send NAS container in Security mode complete message,
Open5GS AMF will send Registration reject message.
The AMF shall assign a new 5G-GUTI for a particular UE:
a) during a successful initial registration procedure;
b) during a successful registration procedure
for mobility registration update; and
c) after a successful service request procedure invoked as a response
to a paging request from the network and before the release
of the N1 NAS signalling connection as specified in subclause 5.4.4.1.
The AMF should assign a new 5G-GUTI for a particular UE
during a successful registration procedure
for periodic registration update. The AMF may assign a new 5G-GUTI
at any time for a particular UE by performing
the generic UE configuration update procedure.
AMF checks whether it can serve all the S-NSSAI(s) from
the Requested NSSAI present in the Subscribed S-NSSAIs
(potentially using configuration for mapping S-NSSAI values
between HPLMN and Serving PLMN), or all the S-NSSAI(s) marked
as default in the Subscribed S-NSSAIs in the case that
no Requested NSSAI was provided or none of the S-NSSAIs
in the Requested NSSAI are permitted,
i.e. do not match any of the Subscribed S-NSSAIs or not available
at the current UE's Tracking Area (see clause 5.15.3).
If both Delete-Session-Request/Response and
UEContextReleaseCommand/UEContextReleaseComplete are failed at the same time,
UE cannot attach to the EPC infinitely.
So, I've add the protection code
if timer expires when MME does not receive Delete-Session-Response.
Previously, AMF would sends PDUSessionResourceSetupRequest
when the following conditions were met:
- gNB didn't send UE Context Request IE of InitialUEMessage
- AMF should send SMF generated TRANSFER message(PDU_RES_SETUP_REQ)
to the gNB
However, in issues #771, the gNB did not accept
PDUSessionResourceSetupRequest. Perhaps the gNB engineer thought
that if gNB needs to send data traffic to the UE, AMF should send
an InitialContextSetupRequest regardless of UE Context Request IE.
This is because gNB requires the kgNB security context
for data connection.
So, in this case, Open5GS-AMF decided to send
an InitialContexSetupRequest regardless of
whether it received UE Context Request IE of InitialUEMessage.
* Flow-Description use 'to assigned' in Gx Interface
* Support SDF Filter ID
* Support F-TEID's Choose
* BAR(Buffering) is added in PFCP session
* Default Apply Action uses NOCP|BUFF
So far, no operation was performed when Error Indication was received
from eNodeB. For that reason, I solved #568 issues by controlling
the MME to prevent this from happening.
Now, when GTP-U Error Indication is received, MME and SGW are implemented
to do what they have to do. I hope that the network can be restored
by responding appropriately even if Error Indication occurs.
<DOWNLINK>
RX : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
GX : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
PFCP : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
RULE : Source <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> Destination <UE_IP> <UE_PORT>
TFT : Local <UE_IP> <UE_PORT> REMOTE <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT>
<UPLINK>
RX : permit in from <UE_IP> <UE_PORT> to <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT>
GX : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
PFCP : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
RULE : Source <UE_IP> <UE_PORT> Destination <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT>
TFT : Local <UE_IP> <UE_PORT> REMOTE <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT>
After the PDN disconnect failed, there was a problem
that the PDN connectivity was not possible again.
PDN connectivity has been modified to work properly
even in the same situation as 401x2 pcap.