A problem occurred when there was one SGWU/UPF and multiple SGWC/SMF.
When SGWU and UPF create a session, if the SEID is the same,
the existing session information is used without creating an additional session.
These problems were solved by using the F-SEID including IP information
in the process of checking the existing session.
* Flow-Description use 'to assigned' in Gx Interface
* Support SDF Filter ID
* Support F-TEID's Choose
* BAR(Buffering) is added in PFCP session
* Default Apply Action uses NOCP|BUFF
<DOWNLINK>
RX : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
GX : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
PFCP : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
RULE : Source <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> Destination <UE_IP> <UE_PORT>
TFT : Local <UE_IP> <UE_PORT> REMOTE <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT>
<UPLINK>
RX : permit in from <UE_IP> <UE_PORT> to <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT>
GX : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
PFCP : permit out from <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT> to <UE_IP> <UE_PORT>
RULE : Source <UE_IP> <UE_PORT> Destination <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT>
TFT : Local <UE_IP> <UE_PORT> REMOTE <P-CSCF_RTP_IP> <P-CSCF_RTP_PORT>
- Set the number of UEs in units of AMF/MME instead of gNB/eNB.
- See default value as shown below
Number of UEs per AMF/MME : 4,096
Number of gNB/eNB per AMF/MME : 32