e1000: Do not read same register twice
EEPROM_INIT_CONTROL2_REG is already read once before entering this switch statement, so there's not much use in reading its value for the second time. Signed-off-by: Andrey Smirnov <andrew.smirnov@gmail.com> Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
This commit is contained in:
parent
2ea081c242
commit
3d68327587
|
@ -839,12 +839,6 @@ static int e1000_setup_link(struct e1000_hw *hw)
|
|||
hw->fc = e1000_fc_full;
|
||||
break;
|
||||
default:
|
||||
ret_val = e1000_read_eeprom(hw, EEPROM_INIT_CONTROL2_REG, 1, &eeprom_data);
|
||||
if (ret_val) {
|
||||
dev_dbg(hw->dev, "EEPROM Read Error\n");
|
||||
return -E1000_ERR_EEPROM;
|
||||
}
|
||||
|
||||
if ((eeprom_data & EEPROM_WORD0F_PAUSE_MASK) == 0)
|
||||
hw->fc = e1000_fc_none;
|
||||
else if ((eeprom_data & EEPROM_WORD0F_PAUSE_MASK) == EEPROM_WORD0F_ASM_DIR)
|
||||
|
|
Loading…