toread is unitialized. We have to use count instead.
| commit 992c291e95
| Author: Sascha Hauer <s.hauer@pengutronix.de>
| Date: Sat Sep 15 16:54:47 2012 +0200
|
| mtd mtdraw: Fix partial page read
|
| When reading parts of a page we have to limit the maximum bytes copied
| to the remaining bytes of a page.