9
0
Fork 0
barebox/dts/Bindings/pwm/cirrus,clps711x-pwm.txt

17 lines
494 B
Plaintext

* Cirris Logic CLPS711X PWM controller
Required properties:
- compatible: Shall contain "cirrus,clps711x-pwm".
- reg: Physical base address and length of the controller's registers.
- clocks: phandle + clock specifier pair of the PWM reference clock.
- #pwm-cells: Should be 1. The cell specifies the index of the channel.
Example:
pwm: pwm@80000400 {
compatible = "cirrus,ep7312-pwm",
"cirrus,clps711x-pwm";
reg = <0x80000400 0x4>;
clocks = <&clks 8>;
#pwm-cells = <1>;
};