; alarmreceiver.conf
|
|
;
|
|
; Sample configuration file for the Asterisk alarm receiver application.
|
|
;
|
|
|
|
|
|
[general]
|
|
|
|
;
|
|
; Specify a timestamp format for the metadata section of the event files
|
|
; Default is %a %b %d, %Y @ %H:%M:%S %Z
|
|
|
|
timestampformat = %a %b %d, %Y @ %H:%M:%S %Z
|
|
|
|
;
|
|
; Specify a command to execute when the caller hangs up
|
|
;
|
|
; Default is none
|
|
;
|
|
|
|
;eventcmd = yourprogram -yourargs ...
|
|
|
|
;
|
|
; Specify a spool directory for the event files. This setting is required if you want the app to be useful.
|
|
; Event files written to the spool directory will be of the template event-XXXXXX, where XXXXXX is a random
|
|
; and unique alphanumeric string.
|
|
;
|
|
; Default is none, and the events will be dropped on the floor.
|
|
;
|
|
|
|
eventspooldir = /tmp
|
|
|
|
;
|
|
; The alarmreceiver app can either log the events one-at-a-time to individual files in the spool
|
|
; directory, or it can store them until the caller disconnects and write them all to one file.
|
|
;
|
|
; The default setting for logindividualevents is no.
|
|
;
|
|
|
|
logindividualevents = no
|
|
|
|
;
|
|
; The timeout for receiving the first DTMF digit is adjustable from 1000 msec. to 10000 msec. The
|
|
; default is 2000 msec. Note: if you wish to test the receiver by entering digits manually, set this
|
|
; to a reasonable time out like 10000 milliseconds.
|
|
|
|
fdtimeout = 2000
|
|
|
|
;
|
|
; The timeout for receiving subsequent DTMF digits is adjustable from 110 msec. to 4000 msec. The
|
|
; default is 200 msec. Note: if you wish to test the receiver by entering digits manually, set this
|
|
; to a reasonable time out like 4000 milliseconds.
|
|
;
|
|
|
|
sdtimeout = 200
|
|
|
|
;
|
|
; The loudness of the ACK and Kissoff tones is adjustable from 100 to 8192. The default is 8192
|
|
; This shouldn't need to be messed with, but is included just in case there are problems with
|
|
; signal levels.
|
|
;
|
|
|
|
loudness = 8192
|
|
|
|
;
|
|
; The db-family setting allows the user to capture statistics on the number of calls, and the errors
|
|
; the alarm receiver sees. The default is for no db-family name to be defined and the database logging
|
|
; to be turned off.
|
|
;
|
|
|
|
;db-family = yourfamily:
|
|
|
|
;
|
|
; End of alarmreceiver.conf
|
|
;
|