1. SCTP event size workaround - stolen code from libosmo-netif
2. Remove PFCP User Plane IP resource information
3. Fix the bug when building Initial Context Setup Request with EMM NAS message.
So far, no operation was performed when Error Indication was received
from eNodeB. For that reason, I solved #568 issues by controlling
the MME to prevent this from happening.
Now, when GTP-U Error Indication is received, MME and SGW are implemented
to do what they have to do. I hope that the network can be restored
by responding appropriately even if Error Indication occurs.
* Add Vendor-Specific-Application-Id in CER of PCRF
Not advertising a Vendor-Specific-Application-Id in CER may result in
Diameter Peer rejecting the CER with a DIAMETER_NO_COMMON_APPLICATION error
* Add Vendor-Specific-Application-Id in CER of HSS and MME
Not advertising a Vendor-Specific-Application-Id in CER may result in
Diameter Peer rejecting the CER with a DIAMETER_NO_COMMON_APPLICATION error
In TS24.501 Ch 5.5.1.3.8 Abnormal cases on the network side
d) REGISTRATION REQUEST with 5GS registration type IE set to
"mobility registration updating" or "periodic registration updating"
received after the REGISTRATION ACCEPT message has been sent and
before the REGISTRATION COMPLETE message is received.
Since, we have to do this special case, it is desirable
to handle it directly inside the state(gmm-sm.c).
After the PDN disconnect failed, there was a problem
that the PDN connectivity was not possible again.
PDN connectivity has been modified to work properly
even in the same situation as 401x2 pcap.
- Set the number of UEs in units of AMF/MME instead of gNB/eNB.
- See default value as shown below
Number of UEs per AMF/MME : 4,096
Number of gNB/eNB per AMF/MME : 32