A problem occurred when there was one SGWU/UPF and multiple SGWC/SMF.
When SGWU and UPF create a session, if the SEID is the same,
the existing session information is used without creating an additional session.
These problems were solved by using the F-SEID including IP information
in the process of checking the existing session.